The OCPP 2.0.1 Device Model

IoTEV ChargingOCPPProtocols
Share on LinkedIn

Your CSMS integration worked with OCPP 1.6 by reading configuration keys like MeterValueSampleInterval and ConnectionTimeOut. The new charger fleet ships with OCPP 2.0.1, and the configuration screen is gone—replaced by a tree of components and variables. The connector is not "available" anymore; Connector.AvailabilityState is Available on EVSE 1 / Connector 1. The Device Model is the structural foundation of OCPP 2.0.1, and every other feature—smart charging, monitoring, firmware updates—builds on it.

Component hierarchy

ChargingStation
├── Controller
│   ├── Clock
│   └── PowerContactor
├── EVSE (id=1)
│   ├── Connector (id=1)
│   │   ├── AvailabilityState
│   │   └── ConnectorType
│   └── Metering
│       ├── Energy.Active.Import.Register
│       └── Power.Active.Import
└── EVSE (id=2)
    └── Connector (id=1)

Each node is a component identified by (name, instance). Each property is a variable with attributes (actual value, target value, mutability).

Variable attributes

Attribute Meaning
Actual Current measured or reported value
Target Desired value (set by CSMS)
MinLimit / MaxLimit Allowed range
Mutability ReadOnly, WriteOnly, ReadWrite
{
  "component": { "name": "Connector", "evse": { "id": 1 }, "connectorId": 1 },
  "variable": { "name": "AvailabilityState" },
  "variableAttribute": [{
    "type": "Actual",
    "value": "Available",
    "mutability": "ReadOnly"
  }]
}

GetVariables and SetVariables

CSMS reads a variable:

// Request
[{
  "component": { "name": "Metering", "evse": { "id": 1 } },
  "variable": { "name": "Energy.Active.Import.Register" }
}]

// Response
[{
  "attributeStatus": "Accepted",
  "variableAttribute": [{ "type": "Actual", "value": "45230.5" }]
}]

CSMS sets a variable:

// Request
[{
  "component": { "name": "Controller" },
  "variable": { "name": "MeterValueSampleInterval" },
  "variableAttribute": [{ "type": "Actual", "value": "60" }]
}]

SetVariables replaces OCPP 1.6 ChangeConfiguration.

Monitoring with NotifyMonitoringReport

OCPP 2.0.1 supports proactive monitoring:

CSMS → SetMonitoringBase (component, variable, severity, threshold)
Charger → NotifyMonitoringEvent (when threshold breached)
{
  "eventData": [{
    "component": { "name": "Metering", "evse": { "id": 1 } },
    "variable": { "name": "Power.Active.Import" },
    "variableMonitoringId": 1,
    "type": "UpperThreshold",
    "severity": 3,
    "actualValue": "22000",
    "thresholdValue": "20000"
  }]
}

Configure monitors for power draw, temperature, and communication health without polling.

Standardized component catalog

OCPP 2.0.1 Part 2 Appendix defines required components:

Component Required variables
ChargingStation AvailabilityState, Problem
EVSE AvailabilityState, AllowedEnergyTransfer
Connector AvailabilityState, ConnectorType
Metering Energy.Active.Import.Register, Power.Active.Import

Vendor-specific components extend the model under a custom namespace. Your CSMS should handle unknown components gracefully.

Implementation approach

Charger firmware:

typedef struct {
    char name[64];
    int evse_id;
    int connector_id;
} Component;

typedef struct {
    char name[64];
    char actual_value[256];
    Mutability mutability;
} Variable;

int get_variable(Component *comp, Variable *var, char *value);
int set_variable(Component *comp, Variable *var, const char *value);

Maintain an in-memory registry mapping component paths to hardware state. Update Actual values on hardware events; validate Target values on SetVariables.

CSMS side: Cache the Device Model per charging station. On connect, send GetBaseReport (ConfigurationInventory or FullInventory) to discover available components.

Migration from OCPP 1.6

OCPP 1.6 OCPP 2.0.1 Device Model
GetConfiguration GetVariables / GetBaseReport
ChangeConfiguration SetVariables
MeterValueSampleInterval key Controller.MeterValueSampleInterval variable
ConnectorPhaseRotation key EVSE.PowerContactor.SupplyPhases variable

Map your 1.6 keys to 2.0.1 component paths during migration.

Monitoring and reporting in OCPP 2.0.1

Device Model enables structured monitoring beyond 1.6's flat configuration:

{
  "setMonitoringLevel": {
    "severity": 3,
    "transactionId": 1
  }
}

Set monitoring levels per component — severity 0 (debug) to 9 (critical). CSMS receives NotifyEvent when monitored variables cross thresholds:

{
  "notifyEvent": {
    "generatedAt": "2024-12-27T10:00:00Z",
    "eventData": [{
      "component": {"name": "EVSE", "evse": {"id": 1}},
      "variable": {"name": "Temperature"},
      "actualValue": "85",
      "trigger": "Alerting",
      "severity": 7
    }]
  }
}

Map NotifyEvent severity to your alerting system — severity ≥7 → PagerDuty, ≥4 → Slack.

Custom components and variables

Beyond the standardized catalog, define vendor-specific components:

{
  "component": {"name": "DisplayUnit", "instance": "1"},
  "variable": {"name": "Brightness"},
  "attributes": [
    {"type": "Actual", "value": "80"},
    {"type": "MinSet", "value": "10"},
    {"type": "MaxSet", "value": "100"}
  ]
}

Custom components extend the model without breaking CSMS compatibility — CSMS ignores unknown components gracefully. Document custom components in your OCPP implementation guide for CSMS partners.

Dual-stack migration strategy

Run OCPP 1.6 and 2.0.1 simultaneously during migration:

Phase 1: OCPP 1.6 production + 2.0.1 pilot on new stations
Phase 2: CSMS supports both protocols; 1.6 stations migrated firmware-by-firmware
Phase 3: 1.6 deprecated; all stations on 2.0.1 Device Model

Maintain a mapping table during dual-stack:

CONFIG_MAP = {
    "MeterValueSampleInterval": "Controller.MeterValueSampleInterval",
    "ConnectorPhaseRotation": "EVSE.PowerContactor.SupplyPhases",
    "HeartbeatInterval": "OCPPCommCtrlr.HeartbeatInterval",
}

Translate 1.6 GetConfiguration responses from 2.0.1 Device Model state — CSMS sees consistent values regardless of protocol version.

Failure modes

Production checklist

Common production mistakes

Teams get ocpp 2 0 1 device model wrong in predictable ways:

Production implementations of ocpp 2 0 1 device model fail when staging mirrors production topology poorly, rollback is untested, and on-call runbooks describe the happy path only.

Resources

Frequently asked questions

How is the OCPP 2.0.1 Device Model different from OCPP 1.6 configuration keys?

OCPP 1.6 uses flat key-value configuration (e.g., MeterValueSampleInterval). OCPP 2.0.1 organizes settings into a hierarchy of components (Controller, EVSE, Connector) and variables (AvailabilityState, SupplyPhases), enabling standardized monitoring, reporting, and firmware management across vendors.

What are the main component types in the Device Model?

ChargingStation (root), EVSE (charging point with connectors), Connector (physical plug), and sub-components like Controller, PowerContactor, and Metering. Each component has variables describing its state and configuration.

Do I need the Device Model if I only use basic charging?

Yes. Even simple Start/Stop transactions in OCPP 2.0.1 reference Device Model variables for connector availability and authorization. Skipping the model means you cannot interoperate with CSMS platforms expecting standard component reporting.